acoustics6 · HYBRID Study B

Acoustic Charts

Visual representations of the MediaVerse acoustic performance data. All values from acoustics6 · HYBRID Study B.

All Charts

RT60 Comparison

Reverberation Time (RT60) target vs. achieved across all octave bands for each room.

Live

NC Curves

Noise Criteria (NC) octave band analysis — NC-12 and NC-18 curves.

Live

Modal Density

Room mode distribution 20–300 Hz for all 3 rooms. Axial modes L, W, H.

Live

STC Wall Comparison

Sound Transmission Class (STC) ratings for all 6 wall assemblies (W1–W6), doors and the observation window.

Live

Quick Reference — RT60 (Reverberation Time) Achieved

RoomTargetAchievedStatus
VO Live0.20 s0.217 s✅ Pass
Control Room0.30 s0.307 s✅ Pass
Video/Podcast (HYBRID)4-state windowsS1 0.332 · S2/S3 0.242 · S4 0.262 s✅ Pass (S2/S3 marginal, disclosed)

Quick Reference — NC (Noise Criteria) Targets

RoomNC TargetHVACSilencer
VO LiveNC-12IDU-04 dedicatedRun A — 1500 mm, 40 dB, 1.5 m/s
Control RoomNC-18IDU-03 sharedRun B — 1000 mm + Run B1 — 500 mm
Video/PodcastNC-18IDU-05 dedicatedRun C — 1000 mm, 25 dB, 2.0 m/s
[AC] Acoustic Critical — Cannot be modified without written approval from the acoustic consultant.    [HP] Hold Point — Stop work and obtain sign-off before proceeding to next phase.    [DEC] Decorative — Can be customized within the stated constraints (color, texture, finish).