Visual representations of the MediaVerse acoustic performance data. All values from acoustics6 · HYBRID Study B.
Reverberation Time (RT60) target vs. achieved across all octave bands for each room.
LiveNoise Criteria (NC) octave band analysis — NC-12 and NC-18 curves.
LiveRoom mode distribution 20–300 Hz for all 3 rooms. Axial modes L, W, H.
LiveSound Transmission Class (STC) ratings for all 6 wall assemblies (W1–W6), doors and the observation window.
Live| Room | Target | Achieved | Status |
|---|---|---|---|
| VO Live | 0.20 s | 0.217 s | ✅ Pass |
| Control Room | 0.30 s | 0.307 s | ✅ Pass |
| Video/Podcast (HYBRID) | 4-state windows | S1 0.332 · S2/S3 0.242 · S4 0.262 s | ✅ Pass (S2/S3 marginal, disclosed) |
| Room | NC Target | HVAC | Silencer |
|---|---|---|---|
| VO Live | NC-12 | IDU-04 dedicated | Run A — 1500 mm, 40 dB, 1.5 m/s |
| Control Room | NC-18 | IDU-03 shared | Run B — 1000 mm + Run B1 — 500 mm |
| Video/Podcast | NC-18 | IDU-05 dedicated | Run C — 1000 mm, 25 dB, 2.0 m/s |